pwm: imx-tpm: Use correct MODULO value for EPWM mode
The modulo register defines the period of the edge-aligned PWM mode
(which is the only mode implemented). The reference manual states:
"The EPWM period is determined by (MOD + 0001h) ..." So the value that
is written to the MOD register must therefore be one less than the
calculated period length. Return -EINVAL if the calculated length is
already zero.
A correct MODULO value is particularly relevant if the PWM has to output
a high frequency due to a low period value.
Fixes: 738a1cfec2
("pwm: Add i.MX TPM PWM driver support")
Cc: stable@vger.kernel.org
Signed-off-by: Erik Schumacher <erik.schumacher@iris-sensing.com>
Link: https://lore.kernel.org/r/1a3890966d68b9f800d457cbf095746627495e18.camel@iris-sensing.com
Signed-off-by: Uwe Kleine-König <ukleinek@kernel.org>
This commit is contained in:
parent
9852d85ec9
commit
cc6a931d1f
@ -106,7 +106,9 @@ static int pwm_imx_tpm_round_state(struct pwm_chip *chip,
|
|||||||
p->prescale = prescale;
|
p->prescale = prescale;
|
||||||
|
|
||||||
period_count = (clock_unit + ((1 << prescale) >> 1)) >> prescale;
|
period_count = (clock_unit + ((1 << prescale) >> 1)) >> prescale;
|
||||||
p->mod = period_count;
|
if (period_count == 0)
|
||||||
|
return -EINVAL;
|
||||||
|
p->mod = period_count - 1;
|
||||||
|
|
||||||
/* calculate real period HW can support */
|
/* calculate real period HW can support */
|
||||||
tmp = (u64)period_count << prescale;
|
tmp = (u64)period_count << prescale;
|
||||||
|