iio: light: opt3001: add missing full-scale range value

The opt3001 driver uses predetermined full-scale range values to
determine what exponent to use for event trigger threshold values.
The problem is that one of the values specified in the datasheet is
missing from the implementation. This causes larger values to be
scaled down to an incorrect exponent, effectively reducing the
maximum settable threshold value by a factor of 2.

Add missing full-scale range array value.

Fixes: 94a9b7b180 ("iio: light: add support for TI's opt3001 light sensor")
Signed-off-by: Emil Gedenryd <emil.gedenryd@axis.com>
Cc: <Stable@vger.kernel.org>
Link: https://patch.msgid.link/20240913-add_opt3002-v2-1-69e04f840360@axis.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Emil Gedenryd 2024-09-13 11:57:02 +02:00 committed by Jonathan Cameron
parent c7c44e5775
commit 530688e39c

View File

@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = {
.val = 20966,
.val2 = 400000,
},
{
.val = 41932,
.val2 = 800000,
},
{
.val = 83865,
.val2 = 600000,